Summary of Results for Cases 1-5
- No difficulties encountered in modal identification
- Damping ratios identified within 4% error
- Frequencies with < 0.1% error
- Damping ratios identified within 15% error (x1=4.5%- Case 5)
- Frequencies within 0.1% error
Case 5 (Damage ii)=6% error (f1=4.03 Hz)